Industrial Emissions Analyzers Selection Guide
Portable Analyzers
Novo | Novo P | S60000 | |
---|---|---|---|
PARAMETERS | |||
# of Gases | 2-4 | 2-4 | 5-6 |
02 Long Life, 0 - 25.0% | ✓ | ✓ | ✓ |
CO, 0 - 8,000 ppm | ✓ | ✓ | ✓ |
Calculated CO2 | ✓ | ✓ | ✓ |
CO2 Sensor for Direct Measurement (0 .. 50%) | - | - | ✓ |
Automatic CO Dilution Auto-Range | ✓ | ✓ | ✓ |
NO sensor 0 - 5,000 ppm | Optional | Optional | ✓ |
NO2 Sensor, 0 - 1,000 ppm | Optional | Optional | Optional |
SO2 Sensor, 0 - 5,000 ppm | Optional | Optional | Optional |
Low NO, NO2, SO2 Sensor, 0 - 100.0 ppm | Optional | Optional | Optional |
CxHy (HC) Pellistor, 0 - 5% vol CH4 | Optional | Optional | Optional |
H2S Sensor (standard or low range) | Optional | Optional | Optional |
H2 Sensor, 0 - 2,000 ppm | Optional | Optional | Optional |
NH3 Sensor, 0 - 500.0 ppm | - | - | Optional |
CH4 NDIR Sensor, 0 - 100% v/v | - | - | Optional |
FEATURES | |||
Built-ln Printer (Non-Fading Paper) | - | ✓ | ✓ |
Wireless Bluetooth® Printer | Optional | - | - |
FIELD-REPLACEABLE Pre-Calibrated Sensors | ✓ | ✓ | ✓ |
Reporting & Storage Software with Bluetooth | ✓ | ✓ | ✓ |
Real-Time Software & Data Logging | - | - | - |
Automatic Data Logging | ✓ | ✓ | ✓ |
Internal Memory (# of Tests) | 100,000 | 100,000 | 2,000 |
External Cooler | Optional | Optional | Optional |
Draft / Differential Pressure | ✓ | ✓ | ✓ |
Gas Velocity | ✓ | ✓ | ✓ |
S9000 and S900-RACK
S9000 | S9000-RACK | |
---|---|---|
PARAMETERS | ||
# of Gases | up to 12 | up to 6 |
Heated Hose & Probe Head | Optional | Optional |
Continuous 24/7 Measurement | - | ✓ |
02 Long Life, 0 - 25.0% | ✓ | ✓ |
CO, 0 - 8,000 ppm | ✓ | ✓ |
Calculated CO2 | - | - |
CO2 Sensor for Direct Measurement (0 .. 50%) | Optional | Optional |
Automatic CO Dilution Auto-Range | ✓ | ✓ |
NO sensor 0 - 5,000 ppm | ✓ | ✓ |
NO2 Sensor, 0 - 1,000 ppm | Optional | Optional |
SO2 Sensor, 0 - 5,000 ppm | Optional | Optional |
Low NOx, SO2 Sensor, 0 - 500.0 ppm | Optional | Optional |
CxHy (HC) Pellistor, 0 - 5% vol CH4 | Optional | Optional |
H2S Sensor (standard or low range) | Optional | Optional |
H2 Sensor, 0 - 2,000 ppm | Optional | Optional |
NH3 Sensor, 0 - 500.0 ppm | Optional | Optional |
NDIR Bench configured for one or more gases of the following: CO2 (0 - 50%), CO (0 -15%) & HC (calibrated for CH4 or C3H3) | Optional | Optional |
FEATURES | ||
Calculated CO2, Efficiency, & Excess Air | ✓ | ✓ |
Built-ln Printer (Non-Fading Paper) | ✓ | - |
Wireless Bluetooth® Printer | - | Optional |
FIELD-REPLACEABLE Pre-Calibrated Sensors | ✓ | ✓ |
Reporting & Storage Software with Bluetooth | ✓ | ✓ |
Real-Time Software & Data Logging | ✓ | ✓ |
Automatic Data Logging | ✓ | ✓ |
Internal Memory (# of Tests) | 16,000 Tests | Data saved via Modbus® on PC |
Built-In Thermo-Electric Peltier Chiller | Optional | ✓ |
Draft / Differential Pressure | ✓ | ✓ |
Gas Velocity | ✓ | ✓ |